Skip to content

← All sections

Estimated energy label of the main building (model, not an energy certificate)

Estimated energy label of the main building with class probabilities and confidence, from a model trained on issued energy certificates. Not an energy certificate and must not be presented as one.

energy_label_estimate18 fieldsNot in the demo
Source
Approach energy_label_estimate model (ordinal, model platform) trained on Enova energy certificates and matrikkel building facts
Geography
The address point
Reported stale after
45 days
Access
Requires a separate agreement (Kartverket Matrikkel)
Contract version
1
In packages
energy_and_power, models

Read about this data source →

Status right now

State
Empty
The source was read but holds no rows. The section answers “no data”, not “no”.
Last loaded
not measured
Data freshness evidence
Empty
Unverified: only collection time is known.
Newest record
not measured
Municipalities with data
0

Measured 10 Nov 2026. This is about the section as a whole, not one address: an address outside coverage still gets “not covered”, never “no”.

Available with: a separate agreement, switched on per account · Ask about an agreement

Model and method

Which energy label is a building without a certificate likely to have?

This is model metadata from the contract. Results are estimates, not observed source facts. Declared maturity and reference comparison do not establish that the current model release is approved or available to the customer.

Result type
Model
Method
Machine learning
Declared maturity
Marked stable in the catalogue
Reference comparison
A reference is declared
Contract version
1
Model artifact and runtime version
Not established by this catalogue description
Inputs, headline fields and comparison basis

Declared inputs

  • Enova energy certificates
  • Matrikkel building facts
  • GRANADA energy wells
  • district-heating areas

Headline output fields

estimated_label, probabilities, confidence

Declared comparison basis

Enova certificates on kommuner held out of the fit, against a building-code-edition baseline

Input names are not a complete training dataset or revision-pinned lineage. Read the caveats and response metadata for what a particular result is based on.

Source terms and reuse

These are declarations from the catalogue contract, not a new rights approval. Customer access, source agreements and privacy need separate assessment. A licence label does not establish coverage or reviewed content.

Declared licence or terms
Kartverket Matrikkel
Declared redistribution
Agreement terms apply
Catalogue basis
Separate agreement
Attribution and note

Shown from the contract in its original language.

Served under a separate agreement; its terms decide what may be shown or passed on.

What this does not say

Quoted verbatim from the section’s warnings field, exactly as the API returns it. They are not translated: a translation would show something other than what your response actually contains.

  • Estimate, not an energy certificate (energiattest): under energimerkeforskriften an energy label is a formal document issued for a specific unit, and this is not one. It must never be presented, sold or used as an energy label, for EU-taxonomy reporting or otherwise, without saying it is a statistical estimate. An issued certificate, where one exists, is in energy_certificates and always takes precedence.
  • The energy_label_estimate model on the model platform: an ordinal (proportional-odds) model with a ridge penalty, fitted on Enova's issued certificates under one regulation (named in regulation; certificates under the 2026 regulation use another scale and are not pooled), newest certificate per building, joined to the building's matrikkel facts: building year and the building code (TEK edition) in force that year, building type, usable area, area per storey, storeys and dwellings, matrikkel energy-source and heating codes, a GRANADA energy well within 50 m and NVE district-heating concession areas, with latitude and elevation as climate proxies (heating degree days are not yet used). estimated_label is the most probable label, confidence its probability, probabilities the full distribution over A-G; label_range is the narrowest run of adjacent labels around it holding at least 80 % of the probability, and uncertainty states the same run in the shared shape (label_index A = 0 to G = 6). The address takes its largest dated building. Rows are computed with the active release named by release_id and the fit named by artifact_sha256.
  • The validation block is the release's held-out figures on kommuner the fit did not see (about a fifth of kommuner, fixed by a hash): within-one-class accuracy, with exact accuracy, log loss, top-class calibration error, the 80 % label range's coverage and the building-code-edition baseline beside it. A release is only built when the fit beats that baseline and is calibrated; until then the section holds no rows. Certificates are not a random sample of buildings (sales and new builds dominate), so accuracy on unlabelled buildings can be lower than measured.
  • Sources: Enova energy certificates (NLOD), Kartverket Matrikkel (by agreement), NGU GRANADA (NLOD), NVE district-heating concessions (NLOD). Model: Approach.
  • Energy-well and district-heating inputs are matches against local source copies, not verified equipment at the building. A false input can also result from an empty local source and does not prove absence of a well, connection or heating system. These negative inputs require source snapshot and coverage qualification before decision use; model probabilities and held-out validation do not establish that coverage.

Provider-contract fields

3 of 18 fields are value fields — the ones that decide whether a record actually says anything. The rest are context: identifiers, codes and timestamps.

FieldTypeRole
methodstring | nullcontext
method_versionstring | nullcontext
model_namestring | nullcontext
model_versioninteger | nullcontext
building_idstring | nullcontext
estimated_labelstring | nullvalue
probabilitiesobject | nullvalue
confidencenumber | nullvalue
expected_label_indexnumber | nullcontext
label_rangearray<string> | nullcontext
uncertaintyobject | nullcontext
regulationstring | nullcontext
inputsobject | nullcontext
model_trained_atstring | nullcontext
release_idstring | nullcontext
artifact_sha256string | nullcontext
validationobject | nullcontext
updated_attimestamp | nullcontext

Fetch this section

Send the key in the X-API-Key header. The section can be fetched with the rest of the address, or on its own with pagination.

curl --disable --fail-with-body --silent --show-error --connect-timeout 10 --max-time 30 \
  -H "X-API-Key: ${APPROACH_API_KEY:?APPROACH_API_KEY is not set}" \
  'https://api.approach.no/api/v1/addresses/285717643?include=energy_label_estimate'

# paginated, one section at a time
curl --disable --fail-with-body --silent --show-error --connect-timeout 10 --max-time 30 \
  -H "X-API-Key: ${APPROACH_API_KEY:?APPROACH_API_KEY is not set}" \
  'https://api.approach.no/api/v1/addresses/285717643/sections/energy_label_estimate?limit=25'

Why it cannot be tried here

This section is not part of the public demo projection. That is a licensing and privacy decision, not a sign the data is missing: it is served to customers granted the section.